Frequently used not only in electric motors but in alternators that operate in humid conditions, such as offshore applications, borehole, marine equipment, pumps, overhead cranes and for all machines that use in tropical applications. The superior design of MEC’s heaters makes them ideal for class F and H applications as well as for electric machines that operate in harsh environments with a lot of vibration.
Their -50° to + 190° temperature range allows these heaters to be used even under extreme conditions. Install the heater on the stator coil before and also after impregnation—cover at least 75% of the windings. If the heater selected is longer than the circumference of the stator, avoid overlapping the ends and leave a distance of at least 6mm to avoid localized overheating.
Temperature range -50°C / + 190°C
Dielectric strength 2.5 kV / 10s
FEP UL 1330 AWG 20 (200°C / 600V) leads